W&T Mode TCP server
Subject to error and alteration
11�1�1 Configuration of the local port number
SETUP Port x
TCP/IP Mode
...
Port List
...
Local Port TCP/UDP
To open a connection to the Com-Server, a client needs an
IP address and the TCP port number. Direct access via TCP
to the serial port of the Com-Server is done using the port
number stored in the menu branch Setup Port x r TCP/IP
Mode r Port List r Local port (TCP). Port number 8000 is pre-
configured at the factory
11�1�2 Optional settings
Serial transmission parameters
SETUP Port x
UART Setup
...
Baud, Parity, Data Bits,
Stopbits, Handshake
Baud rate, data bits, parity and handshake procedure must
conform to the connected serial device. For details see section
Configuration of the Serial Port.
Serial receive buffer
SETUP Port x
UART Setup
...
Receive Buffer
...
The Com-Server has a variable serial receive buffer of approx.
4kB. The menu item allows this value to be reduced. Whether
the serial receive buffer is automatically cleared when a con-
nection is opened or any existing older data are sent to the