169
W&T Mode SLIP router
Subject to error and alteration
21�1�2 Optional settings
Serial transmission parameters
SETUP Port x
UART Setup
...
Baud, Parity, Data Bits,
Stopbits, Handshake
When using in pairs, both Com-Servers used as SLIP routers
must be configured identically for baud rate, parity, data bits
and stop bits.
Software handshake cannot be used as serial flow control in
SLIP mode, since it cannot be precluded that the Xon and Xoff
characters used for this will not occur within the SLIP packets.
Instead, use the hardware handshake settings or – for small
data quantities – NO handshake.
More details can be found in the section Configuration of the
Serial Port.
21�1�3 Deactivating SLIP router mode
Set the parameter Net Address to zero (0.0.0.0) in the SETUP
Port x r TCP/IP Mode r SLIP Router, or use the menu SETUP
Port x r Port State r Clear Port Mode. The Connection State
in the Submenu SETUP Port x r Port State must then be na-
med FREE.