56
W&T The basis configuration of the Com-Server
8�1 Save your settings
When configuring using either Telnet or Web Based Manage-
ment, all the changes are first saved only temporarily in the
Com-Server. To make sure the settings remain intact even
after a reset or power failure, each configuration session must
be ended with an explicit save procedure.
Telnet
From the main menu select SAVE Setup. Respond with y to
the Save Changes ? prompt. If a correct entry was made, the
text Saving… will appear on the monitor, and the Com-Server
saves all the settings you made in its non-volatile memory.
Once the data have been saved, they are activated each time
the Com-Server is turned on or reset.
Entering anything other than y or simply pressing the ENTER
key returns you to the main menu without saving the values.
1
Exceptions are the network parameters IP address,
subnet mask and gateway, since these are also relevant
for the running configuration session. To save and activate
these you must enter q to quit the Telnet configuration after
executing SAVE Setup. The Com-Server then autonomously
performs a reset and only then begins to work with the new
settings.
Browser
Exit the configuration session using the Link Logout and click
on the Save button.