134
W&T Box-to-Box mode
16�1�2 Optional settings
The following optional settings allow enabling/disabling va-
rious special functions. With the exception of TLS(SSL) encryp-
tion these can be set independently of each other on either
the master or the slave.
Serial transmission parameters
SETUP Port x
UART Setup
...
Baud, Parity, Data Bits,
Stopbits, Handshake
Baud rate, data bits, parity and handshake procedure must
conform to the connected serial device. For details see section
Configuration of the Serial Port.
Serial receive buffer
SETUP Port x
UART Setup
...
Receive Buffer
...
The Com-Server has a variable serial receive buffer of approx.
4kB. The menu item allows this value to be reduced. Whether
the serial receive buffer is automatically cleared when a con-
nection is opened or any existing older data are sent to the
application is determined by the Flush Buffer option. Details
can be found in the section Basic configuration of the Com-
Server.
TLS (SSL) Encryption
SETUP Port x
TCP/IP Mode
...
Box to Box
...
TLS(SSL) Encryption
The TCP connection between Box-to-Box master and slave is
TLS/SSL encrypted. When sending time-critical serial protocols