185
W&T Mode InQueueCopy
Subject to error and alteration
23�1�2 Configuring InQueueCopy
SETUP Port x
TCP/IP Mode
...
InQueueCopy
...
Local Copy Port
Accepted Copy-Slave IPs
n Local Copy Port
TCP-Server port on which copies of the serial input data of
the Com-Server are made available. To prevent conflicts
with other standard ports on the Com-Server we recom-
mend selecting a port number > 10,000 as the Local Copy
Port.
Your own TCP socket applications connect directly to this
port number. Serially communicating programs can also
be used for receiving in conjunction with the W&T COM
Port Redirector. In this case the Local Copy Port configu-
red here must be assigned to the virtual COM port.
n
Accepted Copy-Slave IPs
If at least one of the six possible entries is not equal to
0.0.0.0, the Com-Server allows connections to the Local
Copy Port only from the explicitly configured IP addresses.
1
If the InQueueCopy function is activated, the status
as well as the number of slave connections is displayed
in the menu Setup Port x r Port State r Connection State.