64
W&T The basis configuration of the Com-Server
· Read the configuration file (Default = 8003/TCP)
· Write the configuration file (Default = 8004/TCP)
· Reset Com-Server (Default = 8888/TCP)
· Reset Port Status (Default = 9084/TCP)
n
Activate Logfile (Default= 0 = OFF)
A 1 activates recording. In addition the Save Interval must
be configured to a valid value.
n
Save Interval (min) (Default= 0)
Configuration of the time interval in minutes at which the
Logfile is written to the non-volatile memory of the Com-
Server.
1
Saving the Logfile has an influence on the
latencies of the serial data transmission. We re-
commending configuring the Save Interval only as low as
absolutely necessary. When timeouts occur in serial data
exchange, logging should be disabled on a test basis.
n
Delete Logfile
Deletes the entire Logfile including the non-volatile stored
entries.
Reading/Viewing the Logfile
The Logfile can be viewed using the Web Based Management
of the Com-Server under Setup System r Logfile r Load. The
Logfile can be downloaded via TFTP. The name to be specified
in the TFTP client must be wut_cs_logfile. (Note period at the
end!)