CLS200 Series User’s Guide
Chapter 6: Ramp/Soak
125
Using Ramp/Soak
This section explains how to assign a profile to a loop, how to put a profile in RUN or HOLD mode,
how to reset a profile, and how to display profile statistics. Figure 6.4 shows the ramp/soak screens.
ASSIGN R/S
TIME REMAINING
CYCLE NUMBER
SET MODE
RESET
RAMP/
SOAK
RAMP/
SOAK
NO
RAMP/
SOAK
No
Profile
Assigned
Single
Loop
Display
BACK
BACK
BACK
Profile
Assigned
BACK
BACK
YES ENTER
PROFILE
NO
Figure 6.4 — Ramp/Soak Screens
Ramp/Soak Displays
The single loop and bar graph displays show additional codes when ramp/soak firmware is installed.
Single Loop Display
When the controller is running a profile, the single loop display shows the ramp/soak mode where it
would usually show MAN or AUTO. Table 6.4 describes the modes.
Table 6.4Ramp/Soak Single Loop Display
RAMP/SOAK MODE DESCRIPTION
STRT
The profile is in the ready segment.
RUN
The profile is running.
HOLD
The user has put the profile in hold mode.
TOHO
The profile is in tolerance hold.
WAIT
The profile is in trigger wait state.