03/2016 UM-MT-EN-01 77
The time is counted down to zero, and then speed and incline will be set to the first
segment values. Distance and calories are accumulated. The program profile is shown
on the LCD display. The number keys, CLEAR key, and ENTER key are now deactivated.
While the program is running the user can change the incline using the UP/DOWN incline
keys, and the speed using the FAST/SLOW speed keys. The user can interrupt the
training at any time by pressing the PAUSE key. The status of the selected program
lights up to show progress. The signal sounds 3 seconds before the speed and/or incline
changes.
When the PAUSE key is pressed, the treadmill stops. The following information is shown
on the LCD display: "Treadmill Paused. Press PAUSE to resume.” The statistics are
paused when the PAUSE key is pressed. When the user presses the PAUSE key again,
the workout resumes. The CLEAR key is activated during the pause. Pressing the CLEAR
key will reset all the treadmill statistics and return the user to the opening screen (the
LCD display shows the message "Press 'FAST' for Quick Start or select a program").
The statistics are displayed at the bottom of the screen throughout training. Here infor-
mation such as PACE, CALORIES, CALORIES/HR, VERTICAL FEET, and METs can be
found.
When the program is completed, the LCD will read "Program Complete" and the SPEED
is then reset to zero.
When the OFF key is pressed, speed and incline reset to zero and the display will then
switch off.
The heart rate control (only incline) program functions as follows:
If the actual heart rate is 80 beats per minute (BPM) below the target, the incline is
not adjusted. As a result, proper warm-up phase is possible.
If the actual heart rate is 26-80 BPM below the target, the incline will increase 1%
after 15 seconds.
If the actual heart rate is 6-25 BPM below the target, the incline will increase 1%
after 30 seconds.
If the actual heart rate is 3-25 BPM below the target, the incline will increase 0.5%
after 30 seconds.
If the actual heart rate is at least 3 BPM above the target, the incline will decrease
1% after 15 seconds.
There is no adjustment when the actual heart rate deviates from the target by a
maximum of 2 BPM.
This program only controls the speed. The user selects the incline.