Purpose
To outline the general space requirements to enable safe use and adequate access for service.
WARNING
Do not work in a confined space. 1 m (39 inches) space is needed for safe working.
WARNING
USA and Canada. Do not install this machine in a hallway or exit route that does not
have 1.12 m (44 inches) of space additional to the normal space requirements in front of
the machine. To conform with fire regulations this additional 1.12 m (44 inches) of space
is needed in front of the machine in hallway and exit routes.
Procedure
Refer to the following:
Machine Height
Machine Weight
Machine Dimensions and Installation Space Requirements
Machine Height
Basic Machine
Machine with the DADF lowered = 535mm (21 inches)
Machine with the DADF raised = 765mm (30.1 inches)
Machine with Two Trays
Machine with the DADF lowered = 662mm (26 inches)
Machine with the DADF raised = 892mm (35.1 inches)
Machine with Two Trays and Stand
Machine with the DADF lowered = 1103mm
Machine with the DADF raised = 1333mm
Machine Weight
Basic machine = 28.9Kg (63.5lb)
Tray 2 = 7Kg (15.4lb)
Stand = 14.8Kg (32.6lb)