2-44
Phaser 3635MFP
OF5, OF6
Draft 4
Status Indicator RAPs
OF5 Stapler Fault RAP
Use this RAP if the stapler fails to operate.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Refer to Wiring Diagram 9.
1. Check the stapler door interlock switch, go to 01-700 Stapler Door Open RAP.
2. Check the wiring between CON1 on the stapler and CN4 on the Connection PWB.
3. Open the stapler door, PL 28.10 Item 9. Check that the paper present switch actuator
moves freely and actuates the paper present switch.
4. Install new components as necessary:
• Stapler, PL 11.10 Item 3.
• Connection PWB, PL 3.10 Item 17.
OF6 Unable to Boot RAP
Use this RAP if the machine powers up but fails to boot.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Perform the following:
1. Switch off the machine, then switch on the machine.
2. Check the memory DIMM, PL 3.10 Item 10 is correctly installed.
3. If necessary:
a. Install new components:
• Memory DIMM, PL 3.10 Item 10.
• Hard disk drive, PL 3.10 Item 16.
b. Perform OF7 Main PWB Check RAP.