Loading...
4-10
Phaser 3635MFP
REP 3.2
Draft 4
Repairs and Adjustments
REP 3.2 USB PWB and Harness
Parts List on PL 3.10
Removal
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions, GP 10.
1. Remove the DADF, PL 5.10 Item 1.
2. Remove the UI assembly, REP 2.1.
3. Remove the scanner assembly, REP 14.1.
4. Remove the USB harness, PL 3.10 Item 13.
5. Remove the USB host PWB, PL 3.10 Item 11.
Replacement
1. Replacement is the reverse of the removal procedure.