WorkCentre Pro 423/428 2-158 CHAPTER 2 TROUBLESHOOTING
03/02 How to use the Diagnostic C/E Mode
2.4.9.5 Billing/EPSV
Chain Function Item Min.
value
Default Max.
value
Amount of
Change
Adjustment Remarks
25 1 Total number of prints displayed (the present counter
reading) 1
2999997 2999997 No. of copy prints 3 + No. of printer prints 4 + No. of
FAX Prints 5
25 2 Total number of prints (Counter reading at the previous
closing) 2
2999997 2999997 Total number of prints at the previous closing
25 3 No. of copy prints (present counter reading) 3 999999 999999 Writes the data in the backup area as well. Counts up
when the copy print is output normally including Test
Print and Report Print.
25 4 No. of Printer prints (present counter reading) 4 999999 999999 Writes the data in the backup area as well. Counts up
when the copy print is output normally including O/A
Interface Print and Remote Print.
25 5 No. of FAX Prints (present counter reading) 5 999999 999999 Writes the data in the backup area as well. Counts up
when the received print is output normally.
25 6 No. of Copy Prints (Counter reading at the previous closing) 999999 999999 Displays the number of copy prints at the previous
closing.
25 7 No. of Printer Prints (Counter reading at the previous
closing)
999999 999999 Displays the number of printer prints at the previous
closing.
25 8 No. of FAX Prints (Counter reading at the previous closing) 999999 999999 Displays the number of fax prints at the previous
closing.
25 9 No. Copy Prints (present counter reading) SUB 999999 999999 DC Backup Data
25 10 No. Printer Prints (present counter reading) SUB 999999 999999 DC Backup Data
25 11 No. FAX Prints (present counter reading) SUB 999999 999999 DC Backup Data
25 12 No. Copy Prints (present counter reading) IIT 999999 999999 IIT Backup Data
25 13 No. Printer Prints (present counter reading) IIT 999999 999999 IIT Backup Data
25 14 No. FAX Prints (present counter reading) IIT 999999 999999 IIT Backup Data
25 20 M/C serial No. 10bytes ASCII code
The codes applicable to wiring are numerical values
(30hex - 39hex), capital English letters (41hex - 5Ahex)
and Nulls (00hex) only. Any other letters will generate
marginal error.
25 21 M/C model code 8bytes ASCII code.  The codes applicable to wiring are
numerical values (30hex-39hex), capital English letters
(41hex -5Ahex) and Nulls (00hex) only. Any other
letters will generate marginal error.
25 22 Notification of ERU/CRU Switching 0 1 1 0: No notice 1: Notice
25 23 Toner Bomb Notification for Toner Supply Warning 0 0 1 0: No notice 1: Notice
25 24 EPSV Counter Threshold (System Fail) 0 10 127 1 time 0: No notice 1-127: 1 to 127 times
25 25 EPSV Counter Threshold (Local Fail) 0 10 127 1 time 0: No notice 1-127: 1 to 127 times
25 26 EPSV Counter Threshold (Paper Jam) 0 20 127 1 time 0: No notice 1-127: 1 to 127 times
25 27 EPSV Counter Threshold (Document Jam) 0 40 127 1 time 0: No notice 1-127: 1 to 127 times