Chain Function Item Content Default Description
Access
by
57 601** G3M0 TX Modem Speed 1:2400bps 2:4800bps
3:7200bps 4:9600bps
5:12000bps 6:14400bps
7:16800bps 8:19200bps
9:21600bps 10:24000bps
11:26400bps 12:28800bps
13:31200bps 14:33600bps
14 Sets up a starting Modem speed for sending G3 signals.
Individually reflectable on each speed dial (refer to page 2-207)
CE
57 602** G3M0 TX Modem Speed 1:2400bps 2:4800bps
3:7200bps 4:9600bps
5:12000bps 6:14400bps
7:16800bps 8:19200bps
9:21600bps 10:24000bps
11:26400bps 12:28800bps
13:31200bps 14:33600bps
14 Sets up a starting Modem speed for receiving G3 signals. The loading Modem
based on the modem speed setup will be informed to the NSF/DIS signal.
CE
57 603 14400 bps modem type 0=Off 1=V1.7 2=V3.3 & V1.7
3=V3.3
02 Selects a 14400bps modem type for sending and receiving G3 signals. The
ITU-T recommends to use V.17 and this data needs not be changed.
CE
57 610** EQM Comparative data (G3M0) in
4800BPS
0 to 7F FTT send 47(2F) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving 4800bps
CE
57 611** EQM Comparative data (G3M0) in
7200BPS
0 to 7F FTT send 48(30) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving 7200bps
CE
57 612** EQM Comparative data (G3M0) in
9600BPS
0 to 7F FTT send 56(38) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving 9600bps
CE
57 613** EQM Comparative data (G3M0) in
TCM7200BPS
0 to 7F FTT send 70(46) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving TCM7200bps
CE
57 614** EQM Comparative data (G3M0) in
TCM9600BPS
0 to 7F FTT send 64(40) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving TCM9600bpS
CE
57 615** EQM Comparative data (G3M0) in
12000BP
0 to 7F FTT send 64(40) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving 12000bps
CE
57 616** EQM Comparative data (G3M0) in
14400BPS
0 to 7F FTT send 64(40) Determines the standard fall back data based on the EQM(Eye Quality
Monitor) at receiving 14400bps
CE
57 620 Communication Declaration Data Type Total value of
MH=2, MR=4, MMR=8, IMAGE=16,
JBIG=32, Binary=256
318 Selects the coded or composite capability to inform the remote terminal when
sending NSF/DIS signals. The data should not be changed unless otherwise
instructed.
CE
57 623 CCITT MMR capability 0:Off 1:On 01 Selects handling of the MMR capability that can be instructed by ITU-T. The
data should not be changed unless otherwise instructed.
CE
57 624 TCM capability 0:Off 1:On 01 Selects whether or not to enable the TCM capability. The data should not be
changed unless otherwise instructed.