102
Setting
value
Function
Explanation
48
External stop terminal 2
In any control mode (panel control, terminal control, communication
control), the terminal can be used to slow down the frequency
converter, and the deceleration time is fixed as deceleration time 4.
49
Disable Inversion
When the terminal is valid, inverter reverse rotation is prohibited
50
The running time is cleared
When the terminal is valid, the inverter operation time is cleared.
This function needs to be matched and used with the timing
operation (PC-28) and the current operation time (PC-29).
51
Two wire / three wire
switching
Used to switch between two-wire and three-wire mode
Four multi-segment command terminals can be combined into 16 states, each of which corresponds to 16
command settings. The details are as follows:
K4
K3
K2
K1
Command setting
Parameter
OFF
OFF
OFF
OFF
Multi-segment
command 0
PB-00
(PB-16=0)
OFF
OFF
OFF
ON
Multi-segment
command 1
PB-01
OFF
OFF
ON
OFF
Multi-segment
command 2
PB-02
OFF
OFF
ON
ON
Multi-segment
command 3
PB-03
OFF
ON
OFF
OFF
Multi-segment
command 4
PB-04
OFF
ON
OFF
ON
Multi-segment
command 5
PB-05
OFF
ON
ON
OFF
Multi-segment
command 6
PB-06
OFF
ON
ON
ON
Multi-segment
command 7
PB-07
ON
OFF
OFF
OFF
Multi-segment
command 8
PB-08
ON
OFF
OFF
ON
Multi-segment
command 9
PB-09
ON
OFF
ON
OFF
Multi-segment
command 10
PB-10
ON
OFF
ON
ON
Multi-segment
command 11
PB-11
ON
ON
OFF
OFF
Multi-segment
command 12
PB-12
ON
ON
OFF
ON
Multi-segment
command 13
PB-13
ON
ON
ON
OFF
Multi-segment
command 14
PB-14
ON
ON
ON
ON
Multi-segment
PB-15

Table of Contents