110
signal is output after exceeding the threshold. Refer to
function code P7-33-P7-41 for setting motor overload
parameters.
Inverter overload forewarning
The ON signal is output 10s before the overload protection
of inverter.
Refer to communication protocol.
When the set frequency exceeds the upper or lower
frequency, and the frequency of the inverter also reaches the
upper or lower frequency, the ON signal is output.
Frequency 1 arrival output
Frequency 2 arrival output
When the count value reaches the value set by A0-03, the
ON signal is output.
The specified value arrived
When the count value reaches the value set by A0-04, the
ON signal is output. The counting function is shown in the
function description of group A0.
When the power supply of the main circuit and control
circuit of the inverter is stable, and the inverter does not
detect any fault information, and the inverter is in the
operational state, the ON signal is output.
the acquisition value of AI1 is greater than that of AI2, the
ON signal is output
When the value of analog input AI1 is greater than PC-43
(upper limit of AI1 input protection) or less than PC-42
(lower limit of AI1 input protection), the ON signal is
output.
Under voltage state output
When the inverter is under voltage, it outputs ON signal.
When the accumulated power on time (U0-30) of the
inverter exceeds the time set by PC-30, the ON signal is
output.
When the timing function (PC-26) is valid, the inverter will
output ON signal when the running time reaches the set
timing time (PC-28).
When the actual length detected exceeds the length set by
A0-00, the ON signal is output.
Simple PLC cycle completion
When the simple PLC completes a cycle, it outputs a pulse
signal with a width of 250ms.
When the accumulated operation time P8-10 of the inverter
exceeds the time set by PC-32, the ON signal is output.