132
Parameter
Name
Range
P8-02
Parameter initialization
0: No operation
1: Restore factory parameters, excluding motor parameters
(in 3730 and above versions, P0-13 and P0-15 do not
restore factory values)
2: Clear record information
3: Restore factory parameters (including motor parameters)
4: Backup current user parameters (only supported by LCD
panel)
5: Restore user backup parameters (only supported by LCD
panel)
1. Restore factory settings, excluding motor parameters
After P8-02 is set to 1, except for motor parameters, other functional parameters of inverter are restored to
factory parameters.
Note: in 3730 and above versions, after P8-02 is set to 1, except for the motor parameters and the value of
P0-13 and P0-15, other functional parameters of the inverter are restored to the factory parameters,
2. Clear record information
Clear the inverter fault record information, cumulative operation time (P8-10), cumulative power on time
(P8-11), cumulative power consumption (P8-12).
3.Restore factory parameters (including motor parameters)
After setting P8-02=1,most of the functional parameters of the inverter including motor parameters are stored to
the factory parameters. But some parameters such as fault record information, cumulative operation time
(P8-10), cumulative power on time(P8-11), cumulative power consumption (P8-12),module radiator
temperature (P8-19) are not restored.
4.Backup current user parameters (only supported by LCD panel)
Back up the parameters set by user. Back up the settings of all current function parameters.
5. Restore user backup parameters (LCD panel support)
Restore the user parameters previously backed up by setting P8-02=4
Parameter
Name
Range
P8-03
User password
0~65535
If any non-zero number is set in P8-03, the password protection function will take effect. The next time you
enter the menu, you must input the password correctly, otherwise you can't view and modify the function
parameters. Please remember the user password.
If P8-03 is set to 00000, the set user password will be cleared and the password protection function will be
invalid.
Parameter
Name
Range
P8-05
Personalized parameter mode
selection
Ones bit:
0: No display
1: Display user selected parameters
Tens bit: