208
Appendix A-3-2. VH6-B100 (Slot B IO card)
Overview
VH6-B100 is the expansion card of slot B, which can be used when the function or number of IO card of slot A
does not meet the field demand. It has 1 AI, 1 AO, 3 bipolar inputs, 1 YT and 1 YR.
VH6-B100 specifications
Supply 24V power supply for input terminal X. max
output current 200mA. Cannot use for other ways,
only for X terminal power supply.
Supply +10V power supply, max output current 50mA.
Common terminal of
input X
When using the internal power supply to drive the X
terminal:
COM and 24V are short circuited to form NPN input;
COM and 0V are short circuited to form PNP input;
When using the external 24V power supply to drive the
X terminal:
COM is connected to external power supply 24V+,
disconnected from 24V of VH6 to form NPN input;
COM is connected to external power supply 0V,
disconnected from 0V of VH6 to form PNP input;
Optocoupler isolation input; compatible with bipolar
input.
Input impedance: R = 2kΩ;
The input voltage range is 9 ~ 30V.
Open collector output;
Output voltage range: 0-24V;
Output current range: 0-50mA;
Can be high speed pulse output 50KHz.
Programmable defined as multi-function relay output
terminal;
TA-TB: normally open; TA-TC: normally close
Contactor capacity
AC250V/2A (COSΦ=1);
AC250V/1A (COSΦ=0.4);
DC30V/1A.
Input voltage range: -10~10V;
Support PT100;
Select the voltage/PT100 through the DIP switch.
Voltage output range: 0~10V;
Current output range: 0~20mA;
Select voltage / current output by DIP switch.
OFF = -10-10V, ON =PT100 default is OFF
OFF = 0-10V, ON = 0-20mA default is OFF