223
Definition
Modbus address
Function
Note
fault
0014H: Wave by wave current limiting
fault
0015H: Pole position detection failed
0016H: UVW signal feedback error
0017H: Brake resistance short circuit
001AH: SVC stall fault
002BH: External fault
002CH:Communication (timeout)
failure
002DH: EEPORM read / write failure
002EH: Run time arrived
002FH: Power on time arrived
0030H: User defined fault 1
0031H: User defined fault 2
0032H:PID feedback lost during
operation
0033H: Switch motor during operation
0034H: Large speed deviation
0035H: Motor overspeed
0036H: Motor overtemperature
When the frequency is set by communication (P0-03=6),
10000
13-P0
Hz
Data
Frequency
, (Data range:0~10000)
Data can be register or value, user can calculate the Data value according to the above formula when the
frequency is set by communication.
For example, if the maximum output frequency of P0-13 is set to 50Hz, write 10000 to the corresponding
address H1000 of the frequency, and the actual panel displays the frequency value of 100.00*50%=50Hz.
If there is a user password: after writing the correct password, read it within 30s, otherwise it will need to be
written again.