EF
- 93 -
4. Turn the fuel cock lever to
ON.
5. Start the engine and leave it
run until it stops.
The engine stops in approxi-
mately 20 minutes time by
running out of fuel.
TIP
9 Do not connect with any elec-
trical devices. (unloaded oper-
ation)
9 Duration of the running engine
depends on the amount of the
fuel left in the tank.
6. Drain the fuel remaining in the
carburetor into an approved
container by loosening the
drain screw on the carburetor
float chamber.
1 Drain screw
7. Tighten the drain screw.
8. Turn the engine switch to
“STOP”.
9. Turn the fuel cock lever to
OFF.
10. Tighten further if any screws,
bolts and nuts are loose.
11. Store the generator in a dry,
well-ventilated place, with the
cover placed over it.
4 Tournez le levier du robinet de
carburant sur ON.
5. Démarrez le moteur et laissez-
le tourner jusqu’à ce qu’il
s’arrête.
Le moteur s’arrête après envi-
ron 20 minutes en se vidant de
carburant.
N.B.
9 Ne connectez aucun appareil
électrique. (fonctionnement
sans charge)
9 La durée de fonctionnement du
moteur dépend de la quantité
de carburant restant dans le
réservoir de carburant.
6 Vidangez le carburant qui reste
dans le carburateur dans un
récipient approprié en desser-
rant la vis de purge de la cuve
du carburateur.
1 Vis de purge
7. Serrez la vis de purge.
8. Tournez le contacteur du
moteur sur la position
« STOP ».
9. Tournez le levier du robinet de
carburant sur OFF.
10. Si des vis, boulons ou écrous
sont desserrés, serrez d’avanta-
ge.
11. Remisez le générateur à un
endroit sec et bien ventilé, avec
le couvercle posé par-dessus.
7C3-F8199-U0A0_p69-108 12/1/30 4:08 PM Page 93