Specifications
10
10.2 Drive Duty Modes
YASKAWA SIEPC71061753C GA500 Technical Manual 329
10.2 Drive Duty Modes
The drive has two duty modes from which to select for the application: Heavy Duty (HD) and Normal Duty (ND).
Refer to Table 10.1 for information about the differences between HD and ND ratings.
Table 10.1 Drive Duty Modes
Duty Rating
C6-01
Setting
Application Default Carrier Frequency
Overload Tolerance (oL2
[Drive Overload])
Heavy Duty Rating
(HD)
0
Extruder
Conveyor
Cranes and hoists
Constant torque or high overload capacity
Determined by o2-04, A1-02
150% of the rated output current for
60 seconds The permitted
frequency of overload is one time
each 10 minutes.
Normal Duty Rating
(ND)
1
Fan
Pump
Blower
Variable speed control
Determined by o2-04, A1-02
110% of the rated output current for
60 seconds The permitted
frequency of overload is one time
each 10 minutes.

Table of Contents

Other manuals for YASKAWA CIPR-GA50C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIPR-GA50C series and is the answer not in the manual?

YASKAWA CIPR-GA50C series Specifications

General IconGeneral
BrandYASKAWA
ModelCIPR-GA50C series
CategoryController
LanguageEnglish

Related product manuals