Parameter Details
12
12.4 C: Tuning
YASKAWA SIEPC71061753C GA500 Technical Manual 551
Figure 12.39 Example 2: Acceleration/Deceleration Rate (When C1-14 = 40 Hz, E1-04 = 60 Hz, and the Frequency
Reference is 60 Hz)
Figure 12.40 Example 3: Acceleration/Deceleration Rate (When C1-14 = 80 Hz, E1-04 = 60 Hz, and the Frequency
Reference is 60 Hz)
Note:
Figure 12.38 to Figure 12.40 show the accel/decel times when C2-01 to C2-04 [S-Curve Times @ Start/End of Accel/Decel] = 0.00 s.
When L3-01 0 [Stall Prevention during Accel≠ Disabled], Stall Prevention could cause the acceleration time to be longer than the set
value.
When L3-04 0 [Stall Prevention during Decel Disabled], Stall Prevention could cause the deceleration time to be longer than the
set value.
C2: S-Curve Characteristics
Use S-curve characteristics to smooth acceleration and deceleration and to minimize abrupt shock to the load.
Set S-curve characteristic time during acceleration/deceleration at start and acceleration/deceleration at stop.
The following figure explains how S-curves are applied.
Figure 12.41 S-Curve Timing Diagram - Forward/Reverse Operation
Note:
If STPo [Motor Step-Out Detected] occurs when starting a PM motor, try increasing the value set to C2-01.
Setting the S-curve will increase the acceleration and deceleration times.

Table of Contents

Other manuals for YASKAWA CIPR-GA50C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIPR-GA50C series and is the answer not in the manual?

YASKAWA CIPR-GA50C series Specifications

General IconGeneral
BrandYASKAWA
ModelCIPR-GA50C series
CategoryController
LanguageEnglish

Related product manuals