Parameter List
11
11.9 F: Options
YASKAWA SIEPC71061753C GA500 Technical Manual 393
No.
(Hex.)
Name Description
Default
(Range)
Ref.
F7-40
(037C)
Dynamic In Param 8 for
CommCard
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the
values from the MEMOBUS/Modbus address registers stored for each parameter to
Input Assembly 166. The drive returns the default register value for the option card
when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined.
0 622
F7-41
(037D)
Dynamic In Param 9 for
CommCard
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the
values from the MEMOBUS/Modbus address registers stored for each parameter to
Input Assembly 166. The drive returns the default register value for the option card
when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined.
0 622
F7-42
(037E)
Dynamic In Param 10
for CommCard
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the
values from the MEMOBUS/Modbus address registers stored for each parameter to
Input Assembly 166. The drive returns the default register value for the option card
when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined.
0 622
F7-60
(0780)
PZD1 Write (Control
Word)
When you use a Profibus option, set the MEMOBUS/Modbus address for PZD1 (PPO
output). PZD1 (PPO output) functions as the STW when F7-60 = 0 to 2.
0 622
F7-61
(0781)
PZD2 Write (Frequency
Reference)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO
output). PZD2 (PPO output) functions as the HSW when F7-61 = 0 to 2.
0 622
F7-62
(0782)
PZD3 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO
output). A value of 0, 1, or 2 will disable the PZD3 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 622
F7-63
(0783)
PZD4 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO
output). A value of 0, 1, or 2 will disable the PZD4 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 622
F7-64
(0784)
PZD5 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO
output). A value of 0, 1, or 2 will disable the PZD5 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 622
F7-65
(0785)
PZD6 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO
output). A value of 0, 1, or 2 will disable the PZD6 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 623
F7-66
(0786)
PZD7 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO
output). A value of 0, 1, or 2 will disable the PZD7 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 623
F7-67
(0787)
PZD8 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO
output). A value of 0, 1, or 2 will disable the PZD8 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 623
F7-68
(0788)
PZD9 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO
output). A value of 0, 1, or 2 will disable the PZD9 (PPO output) write operation to the
MEMOBUS/Modbus register.
0 623
F7-69
(0789)
PZD10 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10
(PPO output). A value of 0, 1, or 2 will disable the PZD10 (PPO output) write operation
to the MEMOBUS/Modbus register.
0 623
F7-70
(078A)
PZD1 Read (Status
Word)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD1 (PPO
input). PZD1 (PPO input) functions as the ZSW when F7-70 = 0.
0 623
F7-71
(078B)
PZD2 Read (Output
Frequency)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO
input). PZD2 (PPO input) functions as the HIW when F7-71 = 0.
0 623
F7-72
(078C)
PZD3 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD3 (PPO
input). A value of 0 will disable the PZD3 (PPO input) load operation from the
MEMOBUS/Modbus register.
0 623
F7-73
(078D)
PZD4 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD4 (PPO
input). A value of 0 will disable the PZD4 (PPO input) load operation from the
MEMOBUS/Modbus register.
0 624
F7-74
(078E)
PZD5 Read
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD5 (PPO
input). A value of 0 will disable the PZD5 (PPO input) load operation from the
MEMOBUS/Modbus register.
0 624