Parameter Details
12
12.8 H: Terminal Function Selection
YASKAWA SIEPC71061753C GA500 Technical Manual 689
■ H7-04: Virtual Multi-Function Input 4
No.
(Hex.)
Name Description
Default
(Range)
H7-04
(1188)
Expert
Virtual Multi-Function
Input 4
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output 4].
F
(1 - 19F)
■ H7-10: Virtual Multi-Function Output 1
No.
(Hex.)
Name Description
Default
(Range)
H7-10
(11A4)
Expert
Virtual Multi-Function
Output 1
Sets the function for virtual digital output 1.
F
(0 - 1A7)
■ H7-11: Virtual Output 1 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-11
(11A5)
Expert
Virtual Output 1 Delay
Time
Sets the minimum ON time for virtual digital output 1.
0.1 s
(0.0 - 25.0 s)
■ H7-12: Virtual Multi-Function Output 2
No.
(Hex.)
Name Description
Default
(Range)
H7-12
(11A6)
Expert
Virtual Multi-Function
Output 2
Sets the function for virtual digital output 2.
F
(0 - 1A7)
■ H7-13: Virtual Output 2 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-13
(11A7)
Expert
Virtual Output 2 Delay
Time
Sets the minimum ON time for virtual digital output 2.
0.1 s
(0.0 - 25.0 s)
■ H7-14: Virtual Multi-Function Output 3
No.
(Hex.)
Name Description
Default
(Range)
H7-14
(11A8)
Expert
Virtual Multi-Function
Output 3
Sets the function for virtual digital output 3.
F
(0 - 1A7)
■ H7-15: Virtual Output 3 Delay Time
No.
(Hex.)
Name Description
Default
(Range)
H7-15
(11A9)
Expert
Virtual Output 3 Delay
Time
Sets the minimum ON time for virtual digital output 3.
0.1 s
(0.0 - 25.0 s)
■ H7-16: Virtual Multi-Function Output 4
No.
(Hex.)
Name Description
Default
(Range)
H7-16
(11AA)
Expert
Virtual Multi-Function
Output 4
Sets the function for virtual digital output 4.
F
(0 - 1A7)