4.2 Operating Procedures in Parameter Copy Mode
4.2.3 Verifying Parameters (VERIFY)
4-13
4
Parameter Copy Functions
Additional Information on Verifying Parame-
ters
• If an empty block (****) is selected to verify parameters, No Data will
be displayed and nothing will be compared. (Press the Key to
return to the Parameter Block Selection Display.)
• Press the Key to cancel the operation while comparing parame-
ters. Canceled will be displayed and the display will return to the
Parameter Block Selection Display.
• During the comparison operation, the current process will be dis-
played sequentially on the Digital Operator as shown below. The com-
parison operation requires approximately 10 seconds.
• If you specify verifying a parameter block with a SERVOPACK with a
different model, Unmatched Parameters will be displayed and the
parameters will not be compared.
Reading Parameters from the Digital
Operator
Comparing Parameters
Operation Completed
Operation Canceled
00:S GD7S -R70
Reading
Parameters ..
<< OP >>
1:BB VERIFY
1:BB VERIFY
1:BB VERIFY
Verifying
Parameters ..
00:S GD7S -R70
<< OP-S ERVO >>
Canceled
00:
****
1:BB VERIFY
00:S GD7S -R70
Completed