4.2 Operating Procedures in Parameter Copy Mode
4.2.3 Verifying Parameters (VERIFY)
4-13
4
Parameter Copy Functions
Additional Information on Verifying Parame-
ters
If an empty block (****) is selected to verify parameters, No Data will
be displayed and nothing will be compared. (Press the Key to
return to the Parameter Block Selection Display.)
Press the Key to cancel the operation while comparing parame-
ters. Canceled will be displayed and the display will return to the
Parameter Block Selection Display.
During the comparison operation, the current process will be dis-
played sequentially on the Digital Operator as shown below. The com-
parison operation requires approximately 10 seconds.
If you specify verifying a parameter block with a SERVOPACK with a
different model, Unmatched Parameters will be displayed and the
parameters will not be compared.
Reading Parameters from the Digital
Operator
Comparing Parameters
Operation Completed
Operation Canceled
00:S GD7S -R70
Reading
Parameters ..
<< OP >>
1:BB VERIFY
1:BB VERIFY
1:BB VERIFY
Verifying
Parameters ..
00:S GD7S -R70
<< OP-S ERVO >>
Canceled
00:
****
1:BB VERIFY
00:S GD7S -R70
Completed

Table of Contents

Other manuals for YASKAWA E-7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-7 Series and is the answer not in the manual?

YASKAWA E-7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-7 Series
CategoryServo Drives
LanguageEnglish

Related product manuals