n T1-06: Number of Motor Poles (T1-01 = 0)
Sets the number of motor poles according to the motor nameplate value.
n
T1-07: Motor Base Speed (T1-01 = 0)
Used to set the motor rated speed according to the motor nameplate value.
n
T1-08: PG Number of Pulses Per Revolution (T1-01 = 0)
Sets the number of pulses from the PG encoder. Set the actual number of pulses for one full motor rotation.
T1-08 will only be displayed in CLV.
No. Name Setting Range Default
T1-06 Number of Motor Poles 2 to 48 4
No. Name Setting Range Default
T1-07 Motor Base Speed 0 to 24000 r/min 1750 r/min
No. Name Setting Range Default
T1-08 PG Number of Pulses Per Revolution 0 to 60000 ppr 600 ppr