C.9 MEMOBUS/Modbus Data Table
YASKAWA ELECTRIC TOEP C710687 02B FSDrive-MV1000 Instructions 249
MEMOBUS/Modbus
Communications
C
u Broadcast Messages
Data can be written from the master to all slave devices at the same time.
The slave address in a broadcast command message must be set to 00H. All slaves will receive the message, but will not
respond.
u Fault Trace Contents
The table below shows the fault codes that can be read out by MEMOBUS/Modbus commands from the U2- and
U3- monitor parameters.
Table C.5 Fault Trace / History Register Contents
Register No. Contents
0001H
Digital Input Command
bit 0 Forward Run (0: Stop 1: Run)
bit 1 Direction Command (0: Forward, 1: Reverse)
bit 2, 3 Reserved
bit 4 External Fault
bit 5 Fault Reset
bit 6 to B Reserved
bit C Multi-Function Contact Input 5
bit D Multi-Function Contact Input 6
bit E Multi-Function Contact Input 7
bit F Multi-Function Contact Input 8
0002H Frequency Reference 30000/100%
Fault Code Fault Name Fault Code Fault Name
0001H Fuse Blowout (CFA FU) 0098H PWM Feedback Fault (CPF23)
0002H Undervoltage (Uv1) 0099H Drive Unit Signal Fault (CPF24)
0003H Undervoltage (CFA CUV) 009BH ASIC BB Circuit Error (CPF26)
0004H In-rush Prevention Circuit Error (Uv3) 009CH ASIC PWM Setting Register Error (CPF27)
0005H IGBT Fault (CFA IGBT_FLT) 009DH ASIC PWM Pattern Error (CPF28)
0006H Ground Fault (GF) 009EH ASIC On-Delay Error (CPF29)
0007H Overcurrent (CFA OC) 00A0H ASIC Code Error (CPF31)
0008H Overvoltage 1 (CFA OV) 00A1H ASIC Start-p Error (CPF32)
0009H IGBT Overheating (CFA OH) 00A2H Watch-dog Error (CPF33)
000AH IGBT Overheating 1 (CFA OH1) 00A3H ASIC Power/Clock Error (CPF34)
000BH Motor Overload (oL1) 00A9H Control Circuit Error (CPF40)
000CH Drive Overload (oL2) 00AAH Control Circuit Error (CPF41)
000DH Overtorque Detection 1 (oL3) 00ABH Control Circuit Error (CPF42)
000EH Overtorque Detection 2 (oL4) 00ACH Control Circuit Error (CPF43)
0011H External Fault at contact input terminal 3 (EF3) 0101H Option compatibility error (oFA00)
0012H External Fault at contact input terminal 4 (EF4) 0102H Option not properly connected (oFA01)
0013H External Fault at contact input terminal 5 (EF5) 0103H Same type of option card already connected (oFA02)
0014H External Fault at contact input terminal 6 (EF6) 0106H A/D Conversion Error (oFA05)
0015H External Fault at contact input terminal 7 (EF7) 0107H Option Response Error (oFA06)
0016H External Fault at contact input terminal 8 (EF8) 0111H Option RAM Fault (oFA10)
0017H Fan Fault (FAn) 0112H Option Operation Mode Fault (SLMOD) (oFA11)
0018H Overspeed (oS) 0113H Drive Receive CRC Error (oFA12)
0019H Speed Deviation (dEv) 0114H Drive Receive Frame Error (oFA13)
001AH PG Disconnect (PGo) 0115H Drive Receive Abort Error (oFA14)
001CH Output Phase Loss (LF) 0116H Option Receive CRC Error (oFA15)
001EH External Digital Operator Connection Fault (oPr) 0117H Option Receive Frame Error (oFA16)
001FH EEPROM Write Error (Err) 0118H Option Receive Abort Error (oFA17)
0021H MEMOBUS/Modbus Communication Error (CE) 0131H Comm. ID Error (oFA30)
0022H Option Communication Error (bUS) 0132H Model Code Error (oFA31)