200 YASKAWA ELECTRIC TOEP C710687 02B FSDrive-MV1000 Instructions
6.5 Replacing the Cooling Fan
6.5 Replacing the Cooling Fan
NOTICE: Equipment Hazard. Replace the cooling fan with a fan that is specified for use in combination with the drive. Incorrect cooling
fan installation may cause overheating of the drive or degraded performance.
Contact your Yaskawa representative or the nearest Yaskawa sales office to get a cooling fan replaced.
For drives with multiple cooling fans, replace all of the fans when performing maintenance to ensure maximum product
performance life.
u Models and Number of Cooling Fans Used
Table 6.5 Models and Number of Cooling Fans Used
Voltage Class
(kV)
Control
Power Supply
Voltage
(V)
Power Supply
Frequency
(Hz)
Model
CIMR-MV2
Transformer Panel Power Cell Panel
Model/Specifications Qty Model/Specifications Qty
2 200/220 60
AA052
<1>
S3G250-BC54-01,
169W
3
––
AA068
<1>
AA080 <1>
4
AA093
<1>
AA102 <1>
AA115 <1>
AA135 <1>
AA160 <1>
S3G250-BC54-01,
169W
3
AA180
<1>
AA205 <1>
AA220 <1>
AA280 <1>
3
S3G400-KC22-51,
375W
3AA330 <1>
AA390 <1>
AA440 <1>
––––
AA505 <1>
AA550 <1>
AA600 <1>