5.4 Fault Detection
156 YASKAWA ELECTRIC TOEP C710687 02B FSDrive-MV1000 Instructions
Digital Operator Display Fault Name
oFb02 Option Card Fault at Option Port CN5-B
Cause Possible Solutions
An option card of the same type is already
installed in option port CN5-A.
Except for PG options, only one of each option card type can only be installed simultaneously.
An input option card is already installed in
option port CN5-A.
Install a communication option, a digital input option, or an analog input option. More than one
of the same type of card cannot be installed simultaneously.
Digital Operator Display Fault Name
oFb03 to oFb11 Option Card Error Occurred at Option Port CN5-B
oFb12 to oFb17 Option Card Fault at Option Port CN5-B
Cause Possible Solutions
Option card or hardware is damaged.
Cycle control power to the drive.
If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.
Digital Operator Display Fault Name
oFC00 Option Card Connection Error at Option Port CN5-C
Cause Possible Solutions
The option card installed in port CN5-C is
incompatible with the drive.
Confirm that the drive supports the option card to be installed. Contact Yaskawa for assistance.
A communication option card has been
installed in option port CN5-C.
Communication option cards are only supported by option port CN5-A. It is not possible to
install more than one communication option.
Digital Operator Display Fault Name
oFC01 Option Card Fault at Option Port CN5-C
Cause Possible Solutions
The option card installed in port CN5-C has been
changed while operating.
Turn the control power off and reconnect the option card. Check if the option card is properly
plugged into the option port.
The option card connection to port CN5-B is
faulty.
Try to use the card in a different option port (in case of a PG option, use port CN5-B). If the
option card works properly in a different option port, CN5-C is damaged, and the drive requires
replacement. If the error persists (oFA01 or oFb01 occur), replace the option card.
Digital Operator Display Fault Name
oFC02 Option Card Fault at Option Port CN5-C
Cause Possible Solutions
An option card of the same type is already
installed in option port CN5-A or CN5-B.
Except for PG options, only one of each option card type can only be installed simultaneously.
Make sure only one type of option card is connected.
An input option card is already installed in
option port CN5-A or CN5-B.
Install a communication option, a digital input option, or an analog input option. More than one
of the same type of card cannot be installed simultaneously.
Three PG option boards are installed.
A maximum of two PG option boards can be used simultaneously. Remove the PG option board
installed into option port CN5-A.
Digital Operator Display Fault Name
oFC03 to oFC11 Option Card Error Occurred at Option Port CN5-C
oFC12 to oFC17 Option Card Fault at Option Port CN5-C
Cause Possible Solutions
Option card or hardware is damaged.
Cycle control power to the drive.
If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.