5.2 European Standards
234 YASKAWA SIEPC71061737B GA800 Drive Technical Reference
Model EMC Noise Filter Model Quantity Manufacturer
4075A B84243A6083Z000 1 TDK
4089A B84243A6120Z000 1 TDK
4103A B84243A6120Z000 1 TDK
4140A B84243A6180Z000 1 TDK
4168A B84243A6180Z000 1 TDK
4208A B84743A0300R176 1 TDK
4250A B84743A0300R176 1 TDK
4302A B84743A0300R176 1 TDK
4371A B84743B0410S176 1 TDK
4414A B84743B0410S176 1 TDK
4477A B84743A0660S176 1 TDK
4568A B84743A0660S176 1 TDK
4605A B84743A0660S176 1 TDK
4720A B84743A1200S176 1 TDK
DC Link Chokes
To comply with IEC/EN 61000-3-2, install a DC link choke to drive models 2004, 2006, 4002, and 4004 when using
an internal or external EMC filter. Refer to Table 5.10 to select the correct DC link choke.
Table 5.10 DC Link Chokes for Harmonic Suppression (Manufacturer: Yaskawa Electric)
Model DC Link Choke Model Rating
2004 UZDA-B 5.4 A, 8 mH
2006 UZDA-B 5.4 A, 8 mH
4002 UZDA-B 3.2 A, 28 mH
4004 UZDA-B 3.2 A, 28 mH