6 User Defined File
6.3 Setting of File Control Task Priority Limit
6-5
HW1484528
HW1484528
6.3 Setting of File Control Task Priority Limit
Only the normal priority (MP_PRI_TIME_NORMAL) is used as the task
priority for the file control API.
When the file control API is used from the task with higher priority, the
operation differs depending on the setting of the parameter S2C1101 as
shown in the following table.
This setting can also be changed by using “FileControl TASK PRY. LIMIT”
in the maintenance mode.
6.3.1 Changing File Control Task Priority Limit
1. Start in the maintenance mode. Select {Main Menu}, {MotoPlus APL.},
then {MotoPlus FUNC. SETTING}.
2. Press [SELECT] at “FileControl TASK PRY. LIMIT” to select “LIMITED”
or “AUTO”.
S2C1101 FileControl TASK PRY. LIMIT Operation
0 LIMITED The API returns an error.
1
(default
value)
AUTO Temporarily changes the task
priority to MP_PRI_TIME_NORMAL
and executes the API.
45/77