Commands
1
2
3
4
5
6
App
Index
Command Function Page
:MEASure:TRACe<x>:AREA<x>:ALL
Turns ON/OFF all waveform parameters. 5-126
:MEASure:TRACe<x>:
AREA<x>:<Parameter>?
Queries all settings related to the waveform parameter. 5-127
:MEASure:TRACe<x>:
AREA<x>:<Parameter>:COUNt?
Queries the continuous statistical processing count of the waveform
parameter.
5-127
:MEASure:TRACe<x>:AREA<x>:<Para
meter>:{MAXimum|MEAN|MINimum|SD
EViation}?
Queries the statistical value of the waveform parameter. 5-127
:MEASure:TRACe<x>:
AREA<x>:<Parameter>:STATe
Turns ON/OFF the waveform parameter or queries the current setting. 5-127
:MEASure:TRACe<x>:
AREA<x>:<Parameter>:VALue?
Queries the automated measured value of the waveform parameter. 5-128
:MEASure:TRACe<x>:AREA<x>:
DELay:MEASure?
Queries all settings related to the measurement conditions of the source
waveform of the delay measurement between channels.
5-128
:MEASure:TRACe<x>:AREA<x>:
DELay:MEASure:COUNt
Sets the edge detection count of the source waveform of the delay
measurement between channels or queries the current setting.
5-128
:MEASure:TRACe<x>:AREA<x>:
DELay:MEASure:POLarity
Sets the polarity of the source waveform of the delay measurement between
channels or queries the current setting.
5-128
:MEASure:TRACe<x>:AREA<x>:
DELay:REFerence?
Queries all settings related to the reference waveform of the delay
measurement between channels.
5-128
:MEASure:TRACe<x>:AREA<x>:
DELay:REFerence:COUNt
Sets the edge detection count of the reference waveform of the delay
measurement between channels or queries the current setting.
5-129
:MEASure:TRACe<x>:AREA<x>:
DELay:REFerence:POLarity
Sets the polarity of the reference waveform of the delay measurement
between channels or queries the current setting.
5-129
:MEASure:TRACe<x>:AREA<x>:
DELay:REFerence:TRACe
Sets the trace of the reference waveform of the delay measurement between
channels or queries the current setting.
5-129
:MEASure:TRACe<x>:AREA<x>:
DELay:SOURce
Sets the reference of the delay measurement between channels or queries
the current setting.
5-129
:MEASure:TRACe<x>:AREA<x>:
DPRoximal?
Queries all settings related to the distal and proximal values. 5-129
:MEASure:TRACe<x>:AREA<x>:
DPRoximal:MODE
Sets the unit of the distal and proximal values or queries the current setting. 5-129
:MEASure:TRACe<x>:AREA<x>:
DPRoximal:PERCent
Sets the distal and proximal values as a percentage or queries the current
setting.
5-130
:MEASure:TRACe<x>:AREA<x>:
DPRoximal:UNIT
Sets the distal and proximal values in the specified unit or queries the current
setting.
5-130
:MEASure:TRACe<x>:AREA<x>:
METHod
Sets the method for detecting the High/Low level for automated
measurement of waveform parameters or queries the current setting.
5-130
:MEASure:TRANge<x> (Time Range)
Sets the measurement range or queries the current setting. 5-130
:MEASure:WAIT?
Waits for the completion of the automated measurement with a timeout
option.
5-130
:MEASure:WINDow<x>
Sets the measurement source window of the area or queries the current
setting.
5-130
REFerence Group
:REFerence<x>?
Queries all settings related to the reference. 5-131
:REFerence<x>:DISPlay
Turns ON/OFF the display of the reference or queries the current setting. 5-131
:REFerence<x>:INVert
Sets the inverted display of the reference or queries the current setting. 5-131
:REFerence<x>:LABel?
Queries all settings related to the waveform label of the reference. 5-131
:REFerence<x>:LABel[:DEFine]
Sets the waveform label of the reference or queries the current setting. 5-131
:REFerence<x>:LABel:MODE
Turns ON/OFF the waveform label display of the reference or queries the
current setting.
5-131
:REFerence<x>:LOAD
Loads the waveform to the reference. 5-131
:REFerence<x>:POSition
Sets the vertical position of the reference or queries the current setting. 5-131
:REFerence<x>:SELect
Sets the waveform (computation or reference) to the computation channel
or queries the current setting.
5-131
:REFerence<x>:SVALue (Scale
VALUE)
Turns ON/OFF the scale display of the reference or queries the current
setting.
5-131
SEARch Group
:SEARch<x>?
Queries all settings related to the search function. 5-132
:SEARch<x>:ABORt
Aborts the search. 5-132
:SEARch<x>:CLOCk?
Queries all settings related to the clock channel. 5-132
5.1 List of Commands

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL9040 and is the answer not in the manual?

YOKOGAWA DL9040 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL9040
CategoryTest Equipment
LanguageEnglish

Related product manuals