3 - 10 EA3600 Network Connect Product Reference Guide
0x17 Low, high beep
0x18 High, low, high beep
0x19 Low, high, low beep
0x1A High, high, low, low beep
0x22 Low, med, high beep (with vibration) Boot-up sequence.
0x2A Green LED Off
0x2B Green LED On
0x2D Yellow LED On
0x2E Yellow LED Off
0x2F Red LED On
0x30 Red LED Off
0x31 Low, high beep with red LED Parameter entry error.
0x32 Warble with green LED Parameter has been entered.
0x33 Short high, low beep with green LED Numeric key expected.
0x34 Short low, low beep with green LED Alphanumeric character expected.
0x36 Short high, low, low beep with green LED ADF crit/action cleared by user.
0x37 Short low beep with green LED Last ADF rule deleted by user.
0x38 Short low, high, high beep with green LED ADF rule buffer erased by user.
0x3A Short high, high beep with green LED blink Parameter crit/action expected.
0x3C Long low, high, low beep with green LED (blink
off)
ADF rule entry canceled by user.
0x3D Warble with green LED (long light) ADF rules saved.
0x40 Short low, high, high with green LED Parameter defaults set by user.
0x4C Double chirp Volume change.
0x4D High, med, low, high, med, low beeps Internal use.
Table 3-3 Alerts/Actions (Continued)
UIF Code UIF Action Comments