EasyManuals Logo

Zebra TC25 Integrator Guide

Zebra TC25
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
DataWedge
84
Matrix 2 of 5
Length1 - Use to set decode lengths (default - 10). See Decode Lengths on page 85 for more information.
Length2 - Use to set decode lengths (default - 0). See Decode Lengths on page 85 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
Report Check Digit - Transmit Matrix 2 of 5 data with or without the check digit. A check in the checkbox
indicates to send Matrix 2 of 5 data with check digit (default - enabled).
Verify Check Digit - Enable this feature to check the integrity of all Matrix 2 of 5 symbols to verify that the
data complies with a specified check digit algorithm (default - enabled).
MSI
Check Digit - With MSI symbols, one check digit is mandatory and always verified by the reader. The
second check digit is optional.
One Check Digit - Verify one check digit (default).
Two Check Digits - Verify two check digits.
Check Digit Scheme - Two algorithms are possible for the verification of the second MSI check digit.
Select the algorithm used to encode the check digit.
Mod-11-10 - First check digit is MOD 11 and second check digit is MOD 10 (default).
Mod-10-10 - Both check digits are MOD 10.
Length 1 - Use to set decode lengths (default - 4). See Decode Lengths on page 85 for more information.
Length 2 - Use to set decode lengths (default - 55). See Decode Lengths on page 85 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Report Check Digit - Transmit MSI data with or without the check digit. A check in the checkbox indicates
to send MSI data with check digit (default - disabled).
Trioptic 39
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled) (RS6000 only).
UK Postal
Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the checkbox
indicates to send UK Postal data with check digit (default - disabled).
UPCA
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCA preamble:
Preamble None - Transmit no preamble.
Preamble Sys Char - Transmit System Character only (default).
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
Select the appropriate option to match the host system.

Table of Contents

Other manuals for Zebra TC25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra TC25 and is the answer not in the manual?

Zebra TC25 Specifications

General IconGeneral
RAM2 GB
Storage16 GB
Battery Capacity3000 mAh
Rear Camera8 MP
Front Camera2 MP
Display Size4.3 inches
Operating SystemAndroid 7.1.2 (Nougat)
Expansion SlotmicroSD
Connectivity4G LTE
DurabilityMIL-STD 810G