USER MAINTENANCE
Described here are the servicing and preventive maintenance procedures that are required in the day to day operation of
the ProX® DMP 200 printer. The following safety rules are applicable for all procedures.
Caution : the machine is not allowed to run a job during a maintenance.
Caution : perform only tasks you are authorized and certied to complete.
Caution : presence of metal powder. Do not use or manipulate any material without rst reading the
safety datasheet (SDS) for that specic material.
Caution : Personal Protective Equipment (PPE) must be used to protect the user against health or safety
risks during working tasks. Wear disposable rubber gloves (and leather gloves when using a vacuum
cleaner), anti-static coverall, anti-static safety shoes and safety glass. Wear disposable dust mask rated
FFP3 or N99 level protection at minimum ; we recommend the use of powered air-purifying respirator.
WARNING : FINE METAL DUST IS HIGHLY FLAMMABLE. AVOID USING ANY IGNITION SOURCE NEAR THE
MACHINE (OPEN FLAME, SPARKING, ELEVATED TEMPERATURE PARTS).
SERVICING : REPLACEMENT PROCESS FILTERS PROCEDURE
ITEM SPECIFICATION
1500
HOURS
External Filter vessel Replace X

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3D Systems ProX DMP 200 and is the answer not in the manual?

3D Systems ProX DMP 200 Specifications

General IconGeneral
Brand3D Systems
ModelProX DMP 200
Category3D Printers
LanguageEnglish

Related product manuals