803D SYSTEMS, INC.
EVERY 3 MONTHS MAINTENANCE
The following step-by-step procedures must be performed in the provided order.
Procedure to check the glove for damage.
The gloves must be checked at each use of the machine, or at least every 3 months.
Caution: Dust Hazard.
Machine is equipped with rubber gloves to manipulate inside the manufacturing chamber. If rubber
gloves become damaged, ne dust can blow out into the environment. Do not operate the machine with
damaged glove. If glove ripped or punctured during use, dispose of it immediately, and replace it with
new one.
1. Remove the gloves from the machine.
2. Check the presence of defects (cracks, splits, holes, cuts) by visual inspection.
3. Proceed the following steps:
• Grasp the glove,
• Stretch to seal close,
• Roll up the glove by pressing against body,
• Listen for leaks.
4. If glove damaged, replace them with new one:
• Glove reference : 1001619U00