Chiller lter replacement
The chiller lter must be replaced every 6 months.
Parts required :
1 x New lter element - part number 1003282B00
5L container
Demineralized water
Caution: wear PPE (disposable rubber gloves, anti-static coverall, FFP3 respiratory protection, anti-static
safety shoes).
1. Switch off the printer (see section "Shutting printer down" on page 69).
2. Switch off the 2 UPS (see "E. Control/supply cabinet" on page 28).
3. Lock out and tag out the printer: position the main switch from the supply cabinet to position ”O”, then put a lock with a
tag out label on the switch. This will disconnect and isolate the printer from energy during the maintenance.
4. Open the right door of the control/supply cabinet.
5. The lter is located on the right corner. Close the input and output valves (A and B).
6. Unscrew the transparent lter cover and remove it by pulling downwards in order to reveal the inserted lter element.
7. Replace the old lter element with the new one.
8. Screw the transparent lter cover.
9. Open the input and output valves (A and B).
10. Re-start the printer (see section page 33).