893D SYSTEMS, INC.
Gas lter replacement
The gas lter must be replaced every 6 months. The gas lter is located under the front doors.
Part required :
Filter element : 1001884R00.
1. Make sure the gas and purge are not activated.
2. Open the access door located below the fronts door of the machine (1).
3. Remove the lter guard from the lter cap by unscrewing it (2).
Caution : Wear disposable rubber gloves and leather
gloves during the lter guard removal.
4. Remove the lter element. Dispose of it in accordance with all local/regional/national, state and federal regulations.
WARNING : FLAMMABLE POWDERS.
PLACE THE USED FILTER ELEMENT IN A CLOSED METALLIC CONTAINER IN A ROOM WITH FIRE DETECTION.
5. Clean the lter guard with the use of a damp cotton cloth.
6. Install the new lter element.
7. Install the lter guard.
8. Close the access door located below the main cabinet.
1
Filter cap
Filter guard
2