853D SYSTEMS, INC.
6. Dispose of the old element in accordance with all local/regional/national/, state and federal regulations.
WARNING : FLAMMABLE POWDERS.
PLACE THE USED FILTER ELEMENT IN A CLOSED METALLIC CONTAINER IN A ROOM WITH FIRE DETECTION.
7. Clean the lter guard with the use of damp cotton cloth.
8. Assemble the new lter element, and replace it with the lter guard on the machine.
Caution : Make sure to re-use the 2 O-rings (on top and bottom).
Caution : Make sure to t the lter element assembly on the correct position as indicated on the following
gures (removable cap on the top, and centered on the lter guard) .
9. Open the input valve.
10. Close the left side door and the door located below the front doors of the machine.
O-ring
O-ring
Filter guard
Removable cap
Removable cap on the top
Filter element centering: it must be placed on the locating pin of the lter guard.
Locating pin