Actual signals and parameters
Actual signals
The following table includes the descriptions of all actual signal.
Basic signals for monitoring the drive (read-only).
For actual signal supervision, see parameter group 32 SUPERVISION.
For selection of an actual signal to be displayed on the control panel, see parameter
group 34 PANEL DISPLAY.
Calculated motor speed in rpm. A negative value indicates reverse direction.
Calculated motor speed in rpm.
Calculated drive output frequency in Hz. (Shown by default on the panel Output mode
display.)
Measured motor current in A
Calculated motor torque in percent of the motor nominal torque
Measured motor power in kW
Measured intermediate circuit voltage in V DC
Calculated motor voltage in V AC
Measured IGBT temperature in °C
External reference REF1 in Hz
External reference REF2 in percent. 100% equals the maximum motor speed.
Active control location. (0) LOCAL; (1) EXT1; (2) EXT2.
Elapsed drive running time counter (hours). Runs when the drive is modulating. The
counter can be reset by pressing the UP and DOWN keys simultaneously when the
control panel is in the Parameter mode.
kWh counter. The counter value is accumulated till it reaches 65535 after which the
counter rolls over and starts again from 0. The counter can be reset by pressing UP and
DOWN keys simultaneously when the control panel is in the Parameter mode.
Relative value of analog input AI1 in percent
Potentiometer value in percent
Output value of the process PID1 controller in percent
Setpoint signal (reference) for the process PID1 controller. Unit depends on parameter
4006 UNITS and 4007 UNIT SCALE settings.
Feedback signal for the process PID1 controller. Unit depends on parameter 4006 UNITS
and 4007 UNIT SCALE settings.
Deviation of the process PID1 controller, that is the difference between the reference
value and the actual value. Unit depends on parameter 4006 UNITS and 4007 UNIT
SCALE.
Process variable 1 defined by parameter group 34 PANEL DISPLAY
Process variable 2 defined by parameter group 34 PANEL DISPLAY
Process variable 3 defined by parameter group 34 PANEL DISPLAY
Elapsed drive running time counter (thousands of hours). Runs when the drive is
modulating. Counter cannot be reset.
MWh counter. The counter value is accumulated till it reaches 65535 after which the
counter rolls over and starts again from 0. Cannot be reset.