40.80 Set 1 PID output
min source
Selects the source for set 1 PID output minimum. Set1 output
min
None None. 0
Set1 output min 40.36 Set 1 output min.1
Other Source selection (see Terms and abbreviations on page 162). -
40.81 Set 1 PID output
max source
Selects the source for set 1 PID output maximum. Set1 output
max
None None. 0
Set1 output max 40.37 Set 1 output max.1
Other Source selection (see Terms and abbreviations on page 162). -
40.89 Set 1 setpoint
multiplier
Defines the multiplier with which the result of the function
specified by parameter 40.18 Set 1 setpoint function is
multiplied.
1.00
-200000.00…
200000.00
Multiplier. -
40.90 Set 1 feedback
multiplier
Defines the multiplier used in formulas of parameter 40.10
Set 1 feedback function.
1.00
-200000.00…
200000.00
Multiplier. 1 = 1
No. Name/Value Description Def/FbEq16