360 Parameters
96.78 550 compatibility
mode
Enables/disables a Modbus user to access a select set of
parameters using 550 register numbering.
Enable
Disable Using 550 compatibility mode is disabled. 0
Enable Using 550 compatibility mode is enabled. 1
96.100 Change user pass
code
(Visible when user lock is open)
To change the current user pass code, enter a new code into
this parameter as well as 96.101 Confirm user pass code. A
warning will be active until the new pass code is confirmed.
To cancel changing the pass code, close the user lock without
confirming. To close the lock, enter an invalid pass code in
parameter 96.02 Pass code, activate parameter 96.08
Control board boot, or cycle the power.
See also section User lock (page 96).
10000000
10000000…
99999999
New user pass code. -
96.101 Confirm user pass
code
(Visible when user lock is open)
Confirms the new user pass code entered in 96.100 Change
user pass code.
10000000…
99999999
Confirmation of new user pass code. -
96.102 User lock
functionality
(Visible when user lock is open)
Selects the actions or functionalities to be prevented by the
user lock. Note that the changes made take effect only when
the user lock is closed. See parameter 96.02 Pass code.
Note: We recommend you select all the actions and
functionalities unless otherwise required by the application.
0000h
No. Name/Value Description Def/FbEq16
Bit Name Information
0 Disable ABB access
levels
1 = ABB access levels (service, advanced programmer, etc.; see
96.03) disabled
1 Freeze parameter
lock state
1 = Changing the parameter lock state prevented, ie. pass code
358 has no effect
2 Disable file
download
1 = Loading of files to drive prevented. This applies to
firmware upgrades
parameter restore
changing home view of control panel
editing drive texts
editing the favorite parameters list on control panel
configuration settings made through control panel such as
time/date formats and enabling/disabling clock display.
3…6 Reserved
7 Disable panel
Bluetooth
1 = Bluetooth disabled on ACS-AP-W control panel. If the drive is
part of a panel bus, Bluetooth is disabled on all panels.
8...10 Reserved
11 Disable OEM access
level 1
1 = OEM access level 1 disabled
12 Disable OEM access
level 2
1 = OEM access level 2 disabled
13 Disable OEM access
level 3
1 = OEM access level 3 disabled
14…15 Reserved