408 Parameters
DI X113:3 Single input X113:3
DI X113:4 Single input X113:4
DI X114:1 Single input X114:1
DI X114:2 Single input X114:2
DI X114:3 Single input X114:3
DI X114:4 Single input X114:4
FSOGEN.51 Zero speed without
encoder
Sets the zero speed limit for ramp stop
safety functions. Used to define when the
safety function is completed and can be
acknowledged.
Note: This is the absolute value. The same
value is used in both positive and negative
directions.
Note: You cannot set trip limits below this
value.
0.0 rpm
0.0…600.0 rpm Speed
FSOGEN.52 Zero speed with
encoder
Sets the zero speed limit for safe stopping
functions. Used to define when the safety
function is completed and can be
acknowledged.
Note: This is the absolute value. The same
value is used in both positive and negative
directions.
Note: You cannot set trip limits below this
value.
Note: It is recommended to use a value
higher than 0.5 rpm.
0.0 rpm
0.0…600.0 rpm Speed
FSOGEN.61 STO indication ext
request
Sets the type of the event that the FSO
module generates and sends to the drive
after external requests that end to a
successful activation of the drive STO
function (STO, SSE or SS1).
Note: When the FSO module triggers the
STO function in fault situations, it always
generates a fault.
Fault
None No event generated
Fault Fault generated
Warning Warning generated
Event Pure event generated
Index Name/Value Description Factory
default