EasyManua.ls Logo

ABB IRB 2600 - Page 144

ABB IRB 2600
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inspecting additional mechanical stops
Use this procedure to inspect the additional mechanical stops on axis 1.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot work-
ing area.
1
See the figure in:
Location of additional mechanical
stops on page 143
Check the additional mechanical stops on
axis 1 for damage.
2
Tightening torque:
82 Nm
Make sure the stops are properly attached.3
Attachment screws:
M12x40, quality 8.8-A3F
2 pcs/stop lug
If any damage on stops or attachment screws
etc. is detected, the mechanical stops must
be replaced!
4
144 Product manual - IRB 2600
3HAC035504-001 Revision: G
© Copyright 2009-2015 ABB. All rights reserved.
3 Maintenance
3.3.9 Inspecting additional mechanical stops
Continued

Table of Contents