Loading...
Instructions for steam or high pressure water cleaning
ABB robots with protection types Foundry Plus, Wash, or Foundry Prime can be
cleaned using a steam cleaner or high pressure water cleaner.1
The following list defines the prerequisites:
Maximum water pressure at the nozzle: 2,500 kN/m
2
(25 bar)
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum water temperature: 80° C
Cables
Movable cables need to be able to move freely:
Remove waste material, such as sand, dust and chips, if it prevents cable
movement.
Clean the cables if they have a crusty surface, for example from dry release
agents.
Product manual - IRB 2600 187
3HAC035504-001 Revision: G
© Copyright 2009-2015 ABB. All rights reserved.
3 Maintenance
3.5.1 Cleaning the IRB 2600
Continued