NoteEquipment
These procedures include references to the
tools required.
Other tools and procedures may be re-
quired. See references to these procedures
in the step-by-step instructions below.
For spare part no. see chapter Spare parts,
section:
Spare part lists on page 387
SMB unit
Removing the SMB unit
Use this procedure to remove the SMB unit.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
1
A
B
C
xx0900000103
Remove the base cover.2
Parts:
A: Attachment screws (6 pcs)
B: Base cover
C: Cable straps, securing the bat-
tery cable (2 pcs)
Cut the cable straps securing the battery
cable.
3
Continues on next page