NoteEquipment
These procedures include references to the tools
required.
Other tools and procedures may be re-
quired. See references to these proced-
ures in the step-by-step instructions be-
low.
Removing complete tubular shaft unit
Use this procedure to remove the complete tubular shaft unit.
NoteAction
How to drain the oil from the gearbox is
described in section:
Changing the oil, axis-4 gearbox
on page 172
Drain oil from gearbox axis 4.1
xx0800000336
Move the robot to the position shown in the
figure.
2
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
3
xx0800000335
Remove the bracket securing the cable
package to the tubular shaft unit by remov-
ing its attachment screws.
4
Parts:
A: Tubular shaft unit
B: Attachment screws M6x16 qual-
ity 8.8-A2F (2 pcs)
C: Bracket
Continues on next page