EasyManua.ls Logo

ABB IRB 2600 - Page 294

ABB IRB 2600
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
2
See:
Draining gearbox on page 293
Check if the gearbox needs to be drained.3
A
B
xx0800000389
Only applicable to axis-3, axis-4, axis-5 and
axis-6 motors!
Remove the cover in the back of the arm house.
WARNING
The robot must never be run without the cover
in the armhouse fitted! It is a vital supporting
part of the robot.
4
Parts:
A: Cover
B: Attachment screws (8 pcs) +
washers.
How to remove the fan is detailed in
section:
Installation of cooling fan for
motors (option) on page 98
Only applicable to motors on axes 1 and 2
with fan fitted!
Remove the fan before starting the removal!
5
See the figure in:
Location of axis-1 and axis-2
motors on page 286
Only applicable to axis-1 and axis-2 motors!
Remove the motor cover.
6
See the figure in:
Location of axis-1 and axis-2
motors on page 286
Only applicable to axis-1 and axis-2 motors!
Remove the cable gland cover.
7
See the figure in:
Location of axis-1 and axis-2
motors on page 286
Only applicable to axis-1 and axis-2 motors!
Remove the connection box.
Note
Only needed if the motor shall be replaced with
a new one.
8
Continues on next page
294 Product manual - IRB 2600
3HAC035504-001 Revision: G
© Copyright 2009-2015 ABB. All rights reserved.
4 Repair
4.7.1 Removing motors
Continued

Table of Contents

Related product manuals