The motor axis 6 is located as shown in the figure below.
A
R2.MP6
R
2.FB6
B
xx1100000159
A: Metal clamps with nuts (upper arm)
B: Metal clamp (tilthouse)
R2.MP6, R2.FB6 = Connectors to the axis 6 motor
Required equipment
NoteArt.no.Equipment, etc
For spare part no. see:
Spare parts on
page 389
Cable harness, 1-6
Motor, axis 6-Gasket
Content is defined in section
Standard tools on page 383.
-Standard toolkit
Continues on next page
158 Product manual - IRB 460
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness, upper end (incl. axis 6)
Continued