NoteAction
xx1200000950
IRB 6700 - 235/2.65, IRB 6700 - 205/2.80,
IRB 6700 - 175/3.05, IRB 6700 - 150/3.20,
IRB 6700 - 200/2.60, IRB 6700 - 155/2.85
Open the oil plug.4
xx1500001655
IRB 6700 - 300/2.70, IRB 6700 - 245/3.00
xx1300000692
IRB 6700 - 235/2.65, IRB 6700 - 205/2.80,
IRB 6700 - 175/3.05, IRB 6700 - 150/3.20
IRB 6700 - 200/2.60, IRB 6700 - 155/2.85
Check the oil level.
Required oil level is: 58 mm ± 5 mm below
the sealing surface of the oil plug.
5
Continues on next page
Product manual - IRB 6700 121