xx1200000948
Remove the protective cap from the nipple
of the oil hole and connect the oil dis-
penser.
4
xx1200000950
Remove the plug from the vent hole.
WARNING
Open the vent hole while using the dis-
penser, to avoid damaging vital parts in the
gear.
5
Suck out the oil with the oil dispenser.
Note
There will be some oil left in the gear after
draining.
6
WARNING
Used oil is hazardous material and must
be disposed of in a safe way. See section
Decommissioning on page 813 for more in-
formation.
7
Remove the oil dispenser.8
Refit the protective cap on the nipple.
Tightening torque: 24 Nm.Refit the vent hole plug.9